ISKRIT / Laboratory & metrology / Concrete strength · calibration
Laboratory & metrology
Concrete strength and rebound-hammer calibration online
Cube compressive strength and a test report per GOST 10180, a calibration curve for non-destructive testing: the calculator fits a calibration curve for non-destructive testing per GOST 22690 (elastic rebound, impact impulse, pull-off with spalling, rib shearing, plastic deformation) and ultrasound per GOST 17624, and assesses the actual batch class per GOST 18105. Input the specimen failure loads, or pairs of indirect reading and strength; get the series strength, the report, the calibration chart, and a validated curve.
Data current as of 2026-08-24
Standards
GOST 10180-2012: strength from control specimens, scale factors of table 4, series rule of clause 8.4. GOST 22690-2015: calibration curve per appendix E with outlier screening, correlation coefficient and residual standard deviation. GOST 17624-2012: ultrasonic method. GOST 18105-2018: actual batch class by coefficient of variation or scheme G.
Input
Cube edge, failure load, dates. For calibration, pairs of indirect reading and strength.
Output
Series strength, a GOST 10180 report, the calibration equation and chart, its applicable range, the actual batch class.
What it does
- Cube strength with the scale factor to the 150 mm base specimen
- Series strength per the GOST 10180 rule with defective specimens excluded
- Calibration for rebound, impact impulse, ultrasound, pull-off with spalling and rib shearing
- Outlier screening per condition E.6, validity check against correlation 0.7 and residual deviation 15 percent
The tool and the platform
The tool
- Specimen strength and the test report, plus the actual class of the batch
- Calibration for rebound, impulse and ultrasound, tied by a matching factor
- Paste pairs from Excel, a regression chart, export of the report to XLSX
- Calculations are stored on the server and reopen next time, printing and a company letterhead
- Works instantly, no sign-up required
ISKRIT·Site Control demo
The work of a whole department: roles, history and modules linked together.
- A site-wide test log: series, batches and reports pile up on their own
- Acceptance control of batches over a period with accumulated uniformity
- Linked to the instrument fleet: the report shows which calibrated device was used
Questions
Which standards does it use?
Specimen strength and the report per GOST 10180-2012, the calibration curve per GOST 22690-2015 (appendix E) and GOST 17624-2012 for ultrasound, the actual batch class per GOST 18105-2018.
Which non-destructive methods are supported?
Elastic rebound and impact impulse by rebound hammer, ultrasound, pull-off with spalling, rib shearing, plastic deformation. Pick a method and the column, chart and estimate labels follow the instrument indirect reading. A factory curve for a different concrete can be bound to your own with the coincidence coefficient Kc per appendix Ж.
How do I bring data from Excel?
Paste two columns, the indirect reading and the strength. The tool detects the columns and shows the parsed pairs as a table you can review and edit before fitting.
When is a calibration rejected?
If the correlation coefficient is below 0.7 or the residual deviation exceeds 15 percent of the mean strength, the curve is not allowed for strength assessment.